Elcometer
456 Integral Coating Thickness Gaug
Part Number : A456FBI1
Description : Basic
Ferrous Integral Scale 1
Metric : 0 -
100 μm
Imperial : 0-60 mills
|
Elcometer 128 Pictorial Surface Standart
|
Surface Standards include:
BS EN ISO 8501-1:2007/SIS 055900
BS EN ISO 8501-4:2006
The SSPC Standard - VIS 1
The SSPC Standard - VIS 2
The SSPC Standard - VIS 3
The SSPC Standard - VIS 4
The SSPC Standard - VIS 5
|
Elcometer 112 & 3236 Hexagonal Wet Film Comb
|
Formed iAn stainless steel
Sturdy and long lasting
Precise and reuseable
Measure up to 2000 µm (80mils)
|
Precision Foil Sets
Metric and Imperial values displayed on each foil
Available individually certified and individually un-certified, or in
foil sets
Each foil has unique serial number for traceability
Available in thicknesses from
12.5µm to 25mm (0.5 to 980mils)
Precision foils have a ±1% accuracy.
Foils below 50µm (2.0mils) have an accuracy of ±0.5µm (0.02mil).
Metric and Imperial values displayed on each foil
Available individually certified and individually un-certified, or in
foil sets
Each foil has unique serial number for traceability
Available in thicknesses from
12.5µm to 25mm (0.5 to 980mils)
Precision foils have a ±1% accuracy.
Foils below 50µm (2.0mils) have an accuracy of ±0.5µm (0.02mil).
Elcometers 270 Pinhole detectors Inspector's kit
Model
Part Number
Packing List
|
Inspectors Kit
T27018191
Separate wand handle & lead,
roller wand, 10m (33’ signal
return cable, 2 x extension
pieces, telescopic extension,
belt clip, bottle of wetting agent,
3 x AA batteries, spare flat sponge, spare roller
sponge
|
Elcometer 114 Dewpoint Calculator
|
The range of the Elcometer 114 is
-10°C to 50°C (14°F to 122°F) and it has
an accuracy of ±1% of standard tables.
The calculator includes a °C to °F
converter.
|
Elcometer 116 Whirling & Sling Hygrometers
|
Measuring Range
Dimensions
Weight
Packing list
|
-5°C to 50°C (23°F to 122°F)
17 x 22mm (6.9 x 10”)
300g (0.6lb)
Elcometer 116 Whirling Hygrometer or
Elcometer 116 Sling Hygrometer,
slide rule table and operating instructions
|
Elcometers 122 Testex Replica Tape
Profile Range : 38 - 115µm
(1.5 - 4.5mils)
Test area : 19 x 54mm
(0.75 x 2.13”)
Pack of 50 in each rol
|
Elcometer 127
Keane-Tator Surface Comparators & Magnifiers
|
The Elcometer 127 range of Surface Comparators are available in sand,
shot or grit surface profiles.
Each comparator is supplied with 5 profile grades ranging from 0.5 -
5.5mils.
Designed for use with the Elcometer 127 illuminated magnifier, each
comparator has a hole in the centre allowing for clear visual comparisons to
be made.
|
Elcometers 124 Testex Thickness Gauge
|
Range
Dimension
Weight
Scale Resolution
|
: 5mm
: 125 x 95 x 25mm
: 270g
: 2µm
|
Hypodemic Needle Pressure Gauge
|
Pocket sized pressure gauge adapted for use with hypodermic needle to determine
blasting air pressure at the nozzle. Instant readings from 0 - 210 psi
|
Mini Test 650
|
Measuring Range
Measuring Uncertainty
Minimum Curvature Radius
Minimum Measuring Area
Minimum Base Thickness
Display
Measuring Units
Calibration
Statistics
Interface
Power Supply
Dimensions and Weight
Housing
Sensor
Ambient Temperature
Gage
Sensor
|
: Model F (steel) 0 - 3000μm / 120 mils
: ±(2% of reading + 2 μm)
±(2% of reading + 0.08 mils)
: 5 mm / 0.2” convex 25 mm / 1”
concave
: Ø20 mm / 0.8”
: 0.5 mm / 20 mils (F) 50 μm / 2 mils (N)
: 4-digit screen date (11 mm / 0.44”)
: μm - mils user selectable
:Standard, 1-point and 2-point calibration
: Calculated from maximum 9.999
readings, mean value, standard
deviation, number
of readings, minimum and maximum
: USB
: 3 Micro AAA
:
: 2.7 x 4.8 x 1.25 inches / 70 x 122 x 32
mm
: Ø 15mm x 62mm / Ø 0.60” x 2.44”;
225
grams / 7.93 ozs
:
: 0 to 50°C / 32° to 122°F
: -10° to 70°C / 14° to 158°F
|
Surfatest (Wet film Comb) |
Elcometers 124Thickness gauge
![]() |